The AE4536RTSS automated retractable bollard is a high-reliability access control system featuring an IP69 actuator, integrated heating, and a fully programmable control panel for smooth, year-round operation. With proper drainage and routine maintenance, it delivers dependable automated motion, remote control functionality, and optional battery backup for continued performance during power loss.
AE4536RTSS full specifications
Everything from the spec sheet, in one place. The PDF is still under Product Downloads if you need the drawings.
| Cylinder | |
|---|---|
| Cylinder height | 900 mm (35.4 in) |
| Diameter | 114 mm (4.5 in) |
| Wall thickness | 3 mm (0.1 in) |
| Material | AISI 316 stainless steel, brushed finish |
| Operation | |
| Drive | Built-in electromechanical actuator |
| Actuator protection | IP69, not designed to sit under water for long periods |
| Rise time | 6.5 seconds |
| Lowering time | 6.5 seconds |
| Duty rating | Medium frequency, up to 100 cycles per day |
| Service life | About 500,000 cycles |
| Control | Remote transmitters (two included), control panel or mobile app. Works with existing ännt control systems such as transmitters and key selectors. |
| Power and controls | |
| Motor voltage | 24 V (max 3 A) |
| Control unit | Runs up to 4 bollards. Ask us about 5 or more. |
| Connection to control unit | Quick connector, cable not included |
| Field wiring | Per bollard: one 14/2 direct burial cable for the actuator and one for the heater, in 25 mm (1 in) conduit |
| Fusing | 5 A per actuator, 2.5 A per heater |
| Backup power option | UPS with two 12 V 5.2 Ah batteries, up to 40 movements during a power failure. Does not power the heaters. Battery life about 4 years. |
| Foundation | |
| Installation | Ships fully assembled, installation typically takes one day or less |
| Core hole | 356 mm (14 in) per bollard |
| Excavation depth | About 1,524 mm (60 in) |
| Base | 305 mm (12 in) of clear stone, once drainage is confirmed |
| Backfill | 406 to 610 mm (16 to 24 in) of clear gravel around the housing, then concrete |
| Top plate | 6 mm (0.25 in) above finished grade |
| Drainage | Required. A plug and gasket kit is available for sites with ground water. |
| Climate | |
| Operating temperature | -40°C to +70°C (-40°F to +158°F) |
| Cold weather | Heating element and thermostat included, rated to -40°C (-40°F) |
| Shipping | |
| Packaging | 1500 x 220 x 220 mm (59.1 x 8.7 x 8.7 in), each bollard in its own box |
Need a drawing for your foundation design or help choosing the right model? Request information above and our team will send what your project needs.